9.3 Status LED Codes

STATUS LEDs

1 2 3 4 5

Description Action

Random

Cycling

The Link 150 M3 MCU is powering up.

Initialization to follow.

This is not an error and should change to another code

after a minute.

5

Link 150 M3 MCU is initalizing.

Code number will change when finished.

1, 2, 3, or 4

MCU identification number.

Indicates normal operation when it is on steady.

If the same LED is lit on more than one

MCU:

Check the IPC connections.

If the LED is flashing and the ERROR

light is on:

There is a problem with the MCU indicated by the

flashing box ID.

The following

STATUS

LEDs are displayed in combination with the

ERROR

LED.

STATUS LEDs

Description

Action

1, 2, 3, 4, 5

MCU has not been configured for switch

interface type.

Assign a switch type to the MCU. See section 6.3

Install

MCUs -Set Switch Interface T pe

for instructions.

y

1, 3

A Base Station has reported an internal

problem.

Replace the Base Station. In rare cases a problem with

the MCU can cause this error.

2, 3

No communication with one or more

Base Stations on this MCU.

Check cabling to verify that the Base Station’s cable is

plugged into and fully seated in the Base Station port at

the back of the MCU and plugged into the Base Station

at the other end.

If the LED on the Base Station is not lit, check for proper

wiring of the 8-pin modular plugs. See section 5.3

Terminate Cable at Base Station Locations

.

If the cable is over 600 feet long, verify that the extra

wire pairs have been connected correctly.

If the Base Station LED is flashing red, check for open or

shorts on pins 1 and 2 of the cable.

If the Base Station has been removed, acknowledge the

alarm by moving the mode switch to REGISTER. Press

the STEP button until the LED for the removed Base

Station is blinking. Press DEL/ENTER, then move the

mode switch back to NORMAL.

1, 2, 3

Internal communication problem with the

MCU.

Replace the MCU.

4

IPC problem.

Check IPC cabling by disconnecting and reconnecting

the MCUs. Connect the Male RJ-21 connector from the

appropriate demarcation block to the designated RJ-21

connector (A or B) on each MCU. Secure cables using

the keeper.

If the error still occurs try using a different IPC cable.

Replace MCU if the problem still occurs.