Change companding – SpectraLink Link 150 M3 MCU User Manual

Page 45

Advertising
background image

SpectraLink Corporation

Installation and Operation

Link WTS – Link 150 M3 MCU

12.2 Change Companding

The factory setting on the Link 150 M3 MCU is compatible with Mu-law
companding (signal compression), which is the standard used by most PBXs in
North America. Systems outside North America generally use A-law companding. If
the PBX companding is incompatible with the MCU’s, the handsets will have
distorted or hissing dial tone, and voice will be unintelligible.



Before you begin, if the system has more than one MCU, erase the
configurations from all MCUs except MCU 1. Refer to section 9.5 Replace
an MCU
for instructions.

To change the default from Mu- to A-law on the Link 150 M3 MCU follow these
steps.
1. Power the system off.
2. Slide the mode switch on the first MCU to the

ADMIN

position.

3. Power the system on.

STATUS

LEDs

2, 3

, and

4

will be solid green.

4. Press the

STEP

button once.

STATUS

LEDs

2

and

5

will be lit.

5. If the LED for

LINE 1

is lit, the system is set for Mu-law.

If the LED for

LINE 2

is lit, the system is set for A-law.

6. Press the

DEL/ENTER

button to toggle between Mu-law and A-law.

7. When the correct

LINE

LED is lit, return the mode switch to the

NORMAL

position.

PN: 72-0075-01-F.doc