SMC Networks Sunny Mini Central SMC 5000A User Manual

Page 85

Advertising
background image

SMA

Technologie AG

Technical Data

Installation Guide

SMC50A_60A-IEN073320

Page 85

Ripple-Ctl-Frq

The Ripple-Ctl-Frq, Ripple-Ctl-Lev, Ripple-Ctl-Rcvr parameters are
intended to handle ripple control signals from the Sunny Mini
Centrals. These parameters are not available for all Sunny Mini
Centrals. These parameters may only be changed after prior
agreement with SMA Technologie AG.

Ripple-Ctl-Lev

Ripple-Ctl-Rcvr

SMA-SN

Serial number of the Sunny Mini Central.

Software-BFR

Firmware version of the operation control unit (BFR).

Software-SRR

Firmware version of the current control unit (SRR).

Speicherfkt.

Default Parameter: returns all parameters to the factory
settings.

Reset Betriebsdaten: returns all user level parameters to the
factory settings.

Reset Fehler: resets a permanent error.

Speicher/
Storage

Permanent: modified parameters are stored in the EEPROM
and can be used even when the Sunny Mini Central has been
restarted.

Volatil: prevents the parameters being stored in the EEPROM,
the parameters are only stored until the next restart.

T-Max-Fan

Temperature for the maximum fan speed.

T-Start

The period the Sunny Mini Central waits after the Upv-Start value
has been reached.

T-Start-Fan

The fan starts to run at minimum speed at this temperature.

T-Stop

The period the Sunny Mini Central waits before disconnecting from
the grid when Upv drops below the grid peak voltage.

T-Stop-Fan

If after a temperature increase the inverter cools down to below this
threshold value, the fan switches itself off again.

Uac-Max

Lower (Uac-Min) and upper (Uac-Max) limits of the allowable AC
voltage (stand-alone grid recognition), before the grid monitoring
system disconnects the device from the grid.

Uac-Min

Uac-Tavg

Averaging time for measuring grid frequency.

Udc-WindMax

Parameters for adjusting the inverter in Turbine mode. Further
information on this topic can be found in the Windy Boy instruction
manuals.

Udc-WindMid

Udc-WindStart

Upv-Start

The DC voltage required before the Sunny Mini Central begins
feeding power into the grid.

Name

Explanation

Advertising