SMC Networks Sunny Mini Central SMC 5000A User Manual

Page 90

Advertising
background image

Technical Data

SMA

Technologie AG

Page 90

SMC50A_60A-IEN073320

Installation Guide

Sunny Mini Central SMC 6000A

The parameters listed below represent country-specific settings and are only displayed
in installer mode. All other parameters are international and can be viewed in the table
in section 14.4.2.

Name

Short

descr.

Country settings

Germany

Australia

Great

Britain

Italy

Spain

ACVtgRPro

V

253

253

253

253

253

Default

GER/

VDE0126-1-1

AUS/

AS4777

GB/

G83

IT/

DK5950

SP/

RD1663

dFac-Max

Hz/s

4

0.25

0.2

0.20

2

dZac-Max mOhm

670

20000

350

350

350

Fac-delta-

Hz

2,45

0,19

0.5

0.29

0.98

Fac-delta+

Hz

0,19

0,19

0.5

0.29

0.98

I-Ni-Test

mA

16000

8000

0

0

0

LDVtgC

V

0

50

0

50

50

T-Start

s

10

45

180

10

10

Uac-Min

V

198

205

209

198

199

Uac-Max

V

260

265

261

262

250

Advertising
This manual is related to the following products: