3 connection of the dc input, 1 requirements, Connection of the dc input – SMC Networks Sunny Mini Central SMC 5000A User Manual

Page 27: Requirements, 3 connection of the dc input 6.3.1 requirements

Advertising
background image

SMA

Technologie AG

Electrical Connection

Installation Guide

SMC50A_60A-IEN073320

Page 27

6.3 Connection of the DC Input

6.3.1 Requirements

For connecting the DC input, the following requirements must be satisfied:
1.

The connected strings must consist of modules of the same type and number and
should have an identical orientation and tilt.

2.

The connecting wires of the solar modules must be equipped with plug connectors
to allow the eight DC plug connectors of the Sunny Mini Central to be connected
to it.
A pre-assembled set for connecting the free cable ends from a string is available
as an optional accessory from SMA:

3.

Make sure that the following limit values at the DC input of the Sunny Mini Central
are not exceeded:

4.

Check the system design and the string size using the design program Sunny
Design which is available to download free at

www.SMA.de

.

Connection set

Order code

Maximum
flow current

Multi-Contact 3 mm

SWR-MC

21.0 A

Multi-Contact 4 mm

MC-SET

30.0 A

Tyco

TYCO-SET

30.0 A

Device

Maximum
input voltage

Maximum
input current

SMC 5000A

600 V (DC)

26.0 A (DC)

SMC 6000A

600 V (DC)

26.0 A (DC)