14.3 General Data

General Data

Protection rating in accordance
with DIN EN 60529

IP65

Climatic conditions (DIN EN 50178:1998-04):

Location of type C:

class 4K4H
Extended temperature range: -25 °C to +60 °C
Extended humidity range: 0 - 100 %
Extended air pressure range: 79.5 kPa to 106 kPa

Transport of type E:

class 2K3
Temperature range: -25 °C to +70 °C

Max. operating altitude

2000 m above sea level

Fan connections

designed for safe disconnection in accordance with
DIN EN 50178:1998-04

Dimensions (W x H x D)

468 mm x 613 mm x 242 mm (approx.)

External Interfaces

Data transfer via separate
data cable

optional, (RS232 / RS485, galvanically isolated)

Wireless data transmission

optional

Electronic Solar Switch (ESS)

Mechanical service life
(without current):

min. 1,000 switching processes

Electrical service life
(in case of short circuit,
with nominal current of 30 A):

min. 50 switching processes

Max. switching current

30 A

Max. switching voltage

800 V

Max. PV power

approx. 10 kW

Protection rating when
plugged

IP65

Protection rating when
unplugged

IP21