P093, P094, P095 – Siemens Stober CombiDrive CM400/3 User Manual

Page 26: P099, P101, P111, P112, P113, P121, P122

Advertising
background image

English

4. Clear Text Display Module & System Parameters

© STÖBER plc 1998

05.02.01

24

Parameter Function

Range

[Default]

Description / Notes

P093

••••

Serial link timeout (seconds)

0 - 240

[0]

This is the maximum permissible period between two incoming data
telegrams. This feature is used to turn off the inverter in the event of a
communications failure.
Timing starts after a valid data telegram has been received and if a
further data telegram is not received within the specified time period,
the inverter will trip and display fault code F008.
Setting the value to zero switches off the control.

P094

••••

Serial link nominal system
setpoint (Hz)

0 - 120.00

[50.00]

Setpoints are transmitted to the inverter via the serial link as
percentages. The value entered in this parameter represents 100%
(HSW = 4000H).

P095

••••

USS compatibility

0 - 2

[0]

0 = Compatible with 0.1 Hz resolution
1 = Enable 0.01 Hz resolution
2 = HSW is not scaled but represents the actual frequency value to

a resolution of 0.01 Hz (e.g. 5000 = 50 Hz).

P099

••••

Communication adapter type

0 - 1

[0]

0 = Option module not present
1 = PROFIBUS module (enables parameters relating to PROFIBUS)

P101

••••

Operation for Europe or USA

0 - 1

[0]

This sets the inverter for European or USA supply and motor
frequency:

0 = Europe (50 Hz)
1 = USA (60 Hz)

Note: After setting P101 = 1 the

CombiDrive

®

must be reset to

factory defaults. i.e. P944 = 1 to automatically set P013 =
60 Hz, P022 = 60 Hz, P081 = 60 Hz, P082 = 1680 rpm and
P085 will be displayed in hp.

P111

Inverter power rating (kW/hp)

0.0 - 10.00

[œœœ]

Read-only parameter that indicates the power rating of the inverter in
kW. e.g. 0.55 = 550 W
Note:

If P101 = 1 then the rating is displayed in hp.

P112

Inverter type

1 - 8

[8]

Read-only parameter.
1 = MICROMASTER series 2 (MM2)
2 =

CombiDrive

®

3 = MIDIMASTER
4 = MICROMASTER Junior (MMJ)
5 = MICROMASTER series 3 (MM3)
6 = MICROMASTER Vector (MMV)
7 = MIDIMASTER Vector (MDV)
8 =

CombiDrive

®

series 2

P113

COMBIMASTER model

24 - 29

[-]

Read-only parameter.
24 = CM150/3
25 = CM220/3
26 = CM300/3
27 = CM400/3
28 = CM550/3
29 = CM750/3

P121

Enable/disable RUN button

0 - 1

[1]

0 = RUN button disabled.
1 = RUN button enabled (only possible if P007 = 1).

P122

Enable/disable
FORWARD/REVERSE button

0 - 1

[1]

0 = FORWARD/REVERSE button disabled.
1 = FORWARD/REVERSE button enabled (only possible if P007 = 1).