3. Operating Information

© STÖBER plc 1998

05.02.01

10

3. OPERATING INFORMATION

WARNING

The equipment must not be switched on until after its cover has been fitted and the cover
screws have been tightened to the correct torque.

After the power has been turned off, you must always wait one minute so that the dc-link
capacitors can discharge. Do not remove the cover until this time has elapsed.

All settings must only be entered by qualified personnel, paying particular attention to the
safety precautions and warnings.

3.1 General

(1)

The CombiDrive

®

does not have a main power switch and is therefore live when the mains supply is

connected.

(2)

When delivered, the inverter has a frequency setpoint range of between 0 Hz and 50 Hz. Regardless
of its initial position, internal potentiometer R314 must be turned fully counter-clockwise before the
CombiDrive

®

can be started.

R314 can be accessed by removing the right-hand gland hole cover (see Figure 3).

(3)

Parameter settings can only be changed by using either the serial interface (SK200) or an optional
Clear Text Display (OPm2). Refer to the parameter list in section 4 for a full description of each
available parameter.

Connecting a serial link or the OPm2 to the serial interface is made simple by removing the appropriate gland

hole cover (see Figure 3) and plugging a suitably terminated interface cable into the telephone socket
(SK200).

(4)

Analogue input type selection is determined by jumpers JP300 and JP301. JP300 closed selects
current input, JP301 closed (default) selects voltage input. These jumpers can only be accessed while
the cover is removed (see Figure 3).

(5)

If the CombiDrive

®

is run unloaded (e.g. for test purposes) and vibration or trip conditions occur,

change P077 from 0 to 1 (requires OPm2).

3.2 Basic Operation

There are two basic modes of operation for the CombiDrive

®

. Neither mode requires the use of an OPm2 or

serial link connection:

(1)

Using the internal potentiometer only:

(a)

For forward rotation, ensure that a link is fitted between DIN1 (pin 5) and P15+ (pin 8) on PL800 (see
Figure 4a)
. For reverse rotation, connect the link to DIN2 (pin 6) instead of DIN1.

(b)

Apply mains power. The green and yellow LEDs will illuminate to show that power is applied. Turn
potentiometer R314 fully counter-clockwise, otherwise the CombiDrive

®

cannot be started.

(c)

Turn the potentiometer clockwise until the yellow LED extinguishes. This indicates that power is now
applied to the motor. Continue turning clockwise to increase the speed of the motor.

(d)

Turn the potentiometer counter-clockwise to reduce the speed of the motor. Turning the potentiometer
fully counter-clockwise causes the motor to slow to a complete stop. Check that both LEDs are
illuminated (STANDBY mode).