2. Installation

© STÖBER plc 1998

05.02.01

6

2.3 Electrical Installation

Remove the four M5 cross-head screws on the inverter's cover to access the electrical terminals (see Figure 3
and Figure 4)
.

Notes:

(1)

Refer to the electrical data table for cable sizes (see section 6).

(2)

We recommend introducing a `drip loop' when connecting the mains and control cables (see
Figure 5)
.

CAUTION

The printed circuit boards contain CMOS components that are particularly sensitive to static
electricity. For this reason, avoid touching the boards or components with your hands or metal
objects.

Note: Jumper in ‘V’ position = voltage input (default)

Jumper in ‘I’ position = current input

Ensure that the following tightening torques are used:

Electrical terminal screws:

1.1 Nm

Access cover retaining screws:

4.0 Nm

Gland hole covers:

1.0 Nm

IMPORTANT

V

I

JP303

JP302

JP303

Jumpers for

PI Input Type

Default = V

V

I

JP303

JP300

JP301

Jumpers for

Analogue Input Type

Default = V

Mains Connector *

LED

(Green)

LED

(Yellow)

Control Cable Connector

(PL800)

1

12

1

4

OPm2 Connector

(SK200)

Control

Potentiometer

(R314)

L1 L2 L3

-

+

*

Check that the supply voltage is correct for the
COMBIMASTER used by referring to the voltage
code part of the order number (see section 6).

Figure 1: Electrical Connection Diagram