Preset operating modes, Pin assignment d-sub – Siemens 463V FA User Manual

Page 22

Advertising
background image

Colour monitor 463V FA

20 - English

A26361-K864-Z100-1-5E19

Preset operating modes

i

The picture position and size have been set to optimum values at the factory for the
operating modes listed above. Depending on the screen controller used, it may be
necessary to adjust the display position and size. In this case, you can change and save
the settings (see "Operation of the monitor").

The following are the most frequently used of the preset operating modes:

Horizontal frequency

Refresh rate

Screen resolution

31.5 kHz
31.5 kHz
37.5 kHz
37.9 kHz
46.9 kHz
48.4 kHz
60.0 kHz
64.0 kHz
80.0 kHz

70 Hz
60 Hz
75 Hz
60 Hz
75 Hz
60 Hz
75 Hz
60 Hz
75 Hz

720 x 400
640 x 480
640 x 480
800 x 600
800 x 600

1024 x 768
1024 x 768

1280 x 1024
1280 x 1024

For ergonomic reasons, a screen resolution of 1280 x 1024 pixels is recommended. Because of the
technology used (active matrix) an LCD monitor provides a totally flicker-free picture even with a
refresh rate of 60 Hz.

Pin assignment D-SUB

1

5

6

10

11

15

Stylus

Meaning

Stylus

Meaning

1

Video input red

9

+5 V (DDC)

2

Video input green

10

Sync. ground

3

Video input blue

11

Ground

4

Ground

12

DDC-Data

5

Ground

13

H. sync

6

Red video ground

14

V. sync

7

Green video ground

15

DDC Clock

8

Blue video ground

Advertising