13 overheat/fan fail led (oh), Nic1 led, Nic2 led – SUPER MICRO Computer SUPERSERVER 6015B-3 User Manual

Page 47: Hdd led

Advertising
background image

Chapter 5: Advanced Serverboard Setup

5-13

Overheat/Fan Fail LED (OH)

Connect an LED to the OH connection

on pins 7 and 8 of JF1 to provide ad-

vanced warning of chassis overheat-

ing or fan fail. Refer to the table on

the right for pin defi nitions.

NIC1 LED

The NIC1 (Network Interface Control-

ler) LED connection is located on pins

11 and 12 of JF1. Attach the NIC1

LED cable to display network activity.

Refer to the table on the right for pin

defi nitions.

NIC2 LED

The NIC2 (Network Interface Control-

ler) LED connection is located on pins

9 and 10 of JF1. Attach the NIC2

LED cable to display network activity.

Refer to the table on the right for pin

defi nitions.

OH/Fan Fail LED

Pin Defi nitions (JF1)

Pin# Defi nition

7

Vcc

8

Ground

NIC1 LED

Pin Defi nitions (JF1)

Pin# Defi nition

11

Vcc

12

Ground

NIC2 LED

Pin Defi nitions (JF1)

Pin# Defi nition

9

Vcc

10

Ground

HDD LED

The HDD (IDE Hard Disk Drive) LED

connection is located on pins 13 and

14 of JF1. Attach the IDE hard drive

LED cable to display disk activity.

Refer to the table on the right for pin

defi nitions.

HDD LED

Pin Defi nitions (JF1)

Pin# Defi nition

13

Vcc

14

HD Active

Advertising