Hardware monitor logic – SUPER MICRO Computer SUPERSERVER 6015B-3 User Manual

Page 87

Advertising
background image

Chapter 7: BIOS

7-19

Hardware Monitor Logic

CPU Temperature Threshold

(See note on page 7-18.)

This option allows the user to set a CPU temperature threshold that will activate

the alarm system when the CPU temperature reaches this pre-set temperature

threshold. The options are 75

o

C, 80

o

C, 85

o

C, and 90

o

C.

Highlight this and hit <Enter> to see monitor data for the following items:

CPU1 Temperature

CPU1 Second Core

CPU2 Temperature

CPU2 Second Core

System Temperature

Fan1-Fan6 Speeds: If the feature of Auto Fan Control is enabled, the BIOS will

automatically display the status of the fans indicated in this item.

Fan Speed Control Modes

This feature allows the user to decide how the system controls the speeds of the

onboard fans. The CPU temperature and the fan speed are correlative. When the

CPU on-die temperature increases, the fan speed will also increase, and vise versa.

This option is to “3-pin fan” to allow the fan speed to be controlled by voltage. Select

“Disable” to disable the fan speed control function to allow the onboard fans to

run at the full speed (12V) at all the time. The Options are: 1. Disable, 2. 3-pin

(Server), 3. 3-pin (Workstation).

Voltage Monitoring

The following items will be monitored and displayed:

Vcore A

Vcore B

-12V

P1V5

+3.3V

+12V

5Vsb

5VDD

P_VTT

Vbat

Advertising