SUPER MICRO Computer SUPERSERVER 6015B-3 User Manual

Page 65

Advertising
background image

Chapter 6: Advanced Chassis Setup

6-7

2. Installing/removing hot-swap SAS/SATA drives

The SAS/SATA drive carriers are all easily accessible at the front of the chassis.

These hard drives are hot-pluggable, meaning they can be removed and installed

without powering down the system. To remove a carrier, push the release button

located beside the drive LEDs. Then swing the colored handle fully out and use it

to pull the unit straight out (see Figure 6-5).

Note: Your operating system must have RAID support to enable the hot-plug ca-

pability of the SAS/SATA drives.

Figure 6-5. Removing a SAS/SATA Drive from the Server

SAS/SATA Backplane

The SAS drives plug into a SES2 backplane (6015B-3) and the SATA drives plug

into a SAF-TE compliant backplane (6015B-T). Both backplanes provide power,

drive ID and bus termination. A RAID controller can be used with the backplane to

provide data security. The operating system you use must have RAID support to

enable the hot-swap capability of the drives. The backplane is already preconfi g-

ured, so there are no jumpers or switches present on it.

Advertising