Symmetricom Time Server User Manual

Page 135

Advertising
background image

6000-100AppD.fm Rev. D

TimeVault™ User’s Manual

D-121

Symmetricom SNMP Enterprise MIB

Appendix D: SNMP – Simple Network Management Protocol

actsBaudRate OBJECT-TYPE
SYNTAX INTEGER
{
baud300

(300),

baud1200

(1200),

baud9600 (9600),

}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“Indicates the baud rate setting for the ACTS modem. The ACTS
dial-up service accepts 300 or 1200 baud. Note: this is a rare case
where faster is not better and 300 baud yields the best time accuracy.”
::= { acts 2 }

actsFailRedial OBJECT-TYPE
SYNTAX INTEGER (0..9999)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“When the dial-up session fails to connect this is the time in
seconds to wait to try again.”
::= { acts 3 }

actsMaxCallPeriod OBJECT-TYPE
SYNTAX INTEGER (0..999)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“This is the maximum time in minutes the ACTS unit will wait between
successful calls to the ACTS service.”
::= { acts 4 }

actsPhoneNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..25))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“This is the phone number of the ACTS dial-up service, including
any prefixes needed to reach an outside line or international dialing.
Prefixes are separated by a comma from the main phone number.”
::= { acts 5 }

actsNumberOfCalls OBJECT-TYPE
SYNTAX Counter
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“Number of times the time server has called the ACTS dial-up
service - weather the call was successful or not.”
::= { acts 6 }