2 command list, Command list – Symmetricom Time Server User Manual

Page 65

Advertising
background image

6000-100Ch4.fm Rev. D

TimeVault™ User’s Manual

4-51

Command List

Chapter 4: Serial or Telnet I/O Functions

4.2

Command List

The following table lists all serial/Telnet commands that are used to operate, administer,
and maintain the unit. The Utility Port is ready to receive these commands once the
power-up sequence is complete. The F100 series is used mainly to request or set unit NET
Port parameters. Configuration of the IP Address, Subnet Mask, Default Gateway, and
DHCP parameters is also available through the front panel keypad. Changing any
network parameter causes the unit to reboot.

Table 4-1: F-Series Function Commands

Use the front panel keypad to set initial system configuration values at first installation.

Command

Function

Parameters

F03

Time/Date Request

MM/DD/YYYYHH:MM:SS

F18

Software Version Request


(equivalent to F100 VER)

F36

Network Configuration Entry/Request

EA, IP, SM, G
(equivalent to corresponding F100 commands)

F53

Operating Mode Request

F60

Satellite List Request

F67

Leap Second Information Request

F72

Fault Status Request

F100 BASET

100Base-T/10Base-T Entry/Request

10, 100
(change requires confirmation within 10 seconds)

F100 DHCP

DHCP Control

ENABLE/DISABLE
(change requires confirmation within 10 seconds)

F100 EA

Ethernet Address

F100 IP

IP Address

### ### ### ###
(change requires confirmation within 10 seconds)

F100 SM

Subnet Mask

### ### ### ###
(change requires confirmation within 10 seconds)

F100 G

Default Gateway

#### #### #### ####
(change requires confirmation within 10 seconds)

F100 IC

Network Configuration Request

IP, SM, G

F100 P

Password Change Request

XXXXXXX

F100 ST

Self Test Results Request

F100 VER

Software Version Request

F100 T

Request Current Time Source

GPS, ACTS, or NTP

F100 CONFIG

NTP, SNMP and ACTS Configuration

“GET” , “SET”, “NTP”, “SNMP”, “ACTS”, “IP
ADDRESS”, “YES”, “NO”, “W”, “R”
(change requires confirmation within 10 seconds)

F100 LOCK

Remote Lockout

LOCK
(change requires confirmation within 10 seconds)

F100 L

Lock Display Request

Advertising