Symmetricom Time Server User Manual

Page 89

Advertising
background image

6000-100Ch4.fm Rev. D

TimeVault™ User’s Manual

4-75

Extended Function Commands

Chapter 4: Serial or Telnet I/O Functions

timeout

=

after sending a command to the modem, the time
interval, in seconds, that TimeVault waits for a
modem response before timing out

duration

=

duration, in seconds, of a single ACTS session,
starting after the modem detects a carrier

delay

=

reserved for factory calibration only; do not change

period

=

time interval, in minutes, between call attempts

flag

=

set to ON by default; do not change

speed

=

baud rate, set to 9600 by default; reserved for
factory calibration only; do not change

fudge

=

reserved for factory calibration only; do not change

pollcounter

=

determines time precision vs. risk of unsuccessful
call; reserved for factory calibration only; do not
change

center

=

calibration of the phone line; reserved for factory
calibration only; do not change

modemInit

=

modem initialization string; reserved for factory
calibration only; do not change

2. Edit the data in the “acts.conf” file by adding or renaming servers from this list.

3. Return the revised data to TimeVault by sending a “set” command:

F100 config set acts host:192.168.1.14
dir:temp

TimeVault responds:

Are you sure? (y/N)<CR><LF>

If you answer “y”, TimeVault responds as follows*, then resets:

Source file temp/acts.conf bytes read: 149
Dest File/config/acts.conf bytes written: 149
Configuration files transferred successfully!

*<CR><LF> follows each line

As a safety feature, after sending this command, you have 10 seconds to respond
affirmatively (enter the letter “y”) to the confirmation prompt, after which TimeVault
executes the command and resets. Within that 10 second time period, any other response,
including no response, results in TimeVault canceling the command.

When sending a “set” command, the last number in TimeVault’s response (“149” in this

example) represents file length. Depending on your parameters, this number may vary.