4-66

TimeVault™ User’s Manual

6000-100Ch4.fm Rev. D

Chapter 4: Serial or Telnet I/O Functions

Extended Function Commands

4.4.10

F100 VER – Software Version Request

Use Version Request to obtain the software version number of the unit. The version
number is set at compile time, and cannot be changed. It may only be queried.

To query the version number send the following command:

F100<SP>VER<Enter>

where:

F

=

ASCII character F

100

=

unit function number

<SP>

=

space

VER

=

specify Version Request command

<Enter>

=

input line terminator

An example of the response is:

>f100 VER
f100 VER
BOOTLOADER 182-9006v008
SOFTWARE 182-9007v008
FILE SYSTEM 182-9008v008
NVRAM VER 2

4.4.11

F100 T – Current Time Source Request

Use Current Time Source Request to know which time source TimeVault is currently
using.

To query the current time source, send the following command:

F100<SP>T<Enter>

where:

F

=

ASCII character F

100

=

TimeVault function number

<SP>

=

space

T

=

specify Current Time Source Request command

<Enter>

=

input line terminator

An example of the response is:

F100 T GPS <CR><LF>