Schumacher Jump Starter and DC Power Source DC Power Supply IP-1875C User Manual

Page 8

Advertising
background image

• 8 •

12. BEFORE RETURNING FOR REPAIRS

12.1 When a starting problem arises, make certain that the battery is capable of accepting a

normal charge. Double check all connections, the Instant Power™ battery charge level,

the battery clips for correct polarity and the quality of the connections from the cables to

the clips and from the clips to the battery system. The clips must be clean.

12.2 When an UNKNOWN OPERATING PROBLEM arises, please read the complete manual

and call the customer service number for information. This will usually eliminate the

need for return.

If the above solutions do not eliminate the problem, or for information about troubleshooting,

call toll-free from anywhere in the U.S.A.

1-800-621-5485

7:00 am to 5:00 pm Central Time, Monday through Friday

13. SPECIFICATIONS

Internal Battery Type

Maintenance-free AGM Lead-acid

Nominal Voltage

12V DC

Capacity

18 Ah

DC Power Outlet (Max. Continuous Load)

15A

Peak Amps

950

Jumper Cables

4-gauge AWG (21.14 mm

2

), 28" (71 cm)

Dimensions (H x W x D)

11 x 12.75 x 7 Inches (28 x 32.5 x 17.75 cm)

Product Weight

19 lbs. (8.5 kg)

14. REPLACEMENT PARTS/ACCESSORIES

Male-To-Male Accessory Cable ......................................................................... 94500109
Air Compressor Accessory Kit (3 Adapters) ................................................... 0099000599

Battery Clip Jaw Replacement Kit .................................................................. 2299001580

14.1 Battery Clip Replacement

1. Make sure the ON/OFF switch on the front panel is in the OFF (O) position and the

Instant Power™ is not plugged into a 120V AC wall outlet.

2. Secure the clamp in the open position using a vise or equivalent clamping device.

WARNING: The clips are spring-loaded, so use caution when replacing the jaws, to

avoid injury.

3. Remove the rear screw that attaches the Instant Power™ cable to the jaw.
4. Remove the screw holding the copper jaw to the plastic clip. Repeat for other jaw.
5. Remove the two jaws and braided cable.
6. Reverse the steps to install the replacement parts.

Advertising