12

TECHNICAL SPECIFICATIONS

MODEL

FUNCTIONS

ACCESSORY

COOLING CAPACITY (W)

HEATING CAPACITY (W)

POWER SUPPLY

FREQUENCY

COOLING / HEATING RATED CURRENT

MAXIMUM INPUT CURRENT

COOLING / HEATING RATED POWER

COOLING / HEATING RATED INPUT

RECYCLING AIR VOLUME (m

3

/h)

REFRIGERANT AND WEIGHT

WATER PROOF LEVEL

NOISE (INDOOR / OUTDOOR) dB (A)

CLIMATE TYPE

ANTI-ELECTRIC SHOCK PROTECTION

WEIGHT (KG) INDOOR UNIT / OUTDOOR UNIT

SUCTION CONNECTION SIZE

LIQUID CONNECTION SIZE

13-05020 / 13-05024

Cool/Heat

Air cleaner

2,500 W (1,350-3,200 W)

2,700 W (1,750-4,000 W)

115 V

60 Hz

3.53/3.86 A

6.0 A

1,360/1,390 W

730/800 W

450 W

R410A/1.2 kg

IP24

40/53 dBA

T1

I

8.5/45 kg

1/2”

1/4”

83 x 28.5 x 22.5 cm

84.8 x 54 x 32 cm

Working temperature range

Maximum cooling

32/23

43/26

Minimum cooling

21/15

21/-

Maximum heating

27/-

24/18

Minimum heating

20/-

-5/-6

Indoor side

DB/WB(°C)

Outdoor side

DB/WB(°C)

1. Above information may change without notice. Accurate specifications can can be found on the

name plate located on the unit.

2. When the unit is restarted after it was stopped, it can automatically resume in its most latest

running mode, and the outdoor unit starts a little bit later.

Do not operate unit if outside temperature range as shown below, or you could damage
compresssor and void the warranty

INDOOR UNIT

OUTDOOR UNIT

DIMENSION (cm)

W X H X D

Advertising
This manual is related to the following products: