15

INSTALLATION INSTRUCTIONS

INSTALL THE REAR PANEL

1. Always mount the rear panel horizontally.
2. Fix the rear panel on the selected location

with screws supplied with the unit.

3. Be sure that the rear panel has been fixed

firmly enough to withstand the weight of an
adult of 60 kg (132.3 lbs.), furthermore, the
weight should be evenly shared by each
screw.

INSTALL THE DRAIN HOSE

1. For a proper draining, the drain hose should be

placed at a downward slant.

2. Do not wrench or bend the drain hose or

flood its end in water.

3. The extended drainage pipe in the room should be wrapped with the insulating materials.

INSTALL THE PIPING HOLE

1. Make the piping hole 50 mm (2”) in the wall at a slight downward slant to the outdoor side.

The center of the hole should be determined refer to Fig.2.

2. Insert the piping-hole sleeve into the hole to prevent the connection piping and wiring

from being damaged when passing through the hole.

INSTALL THE CONNECTION PIPES

Connect the connection pipes with the relevant union pipes of the indoor unit of the
indoor unit and tighten the flare nut of the connection pipes.
NOTE:
• Connect the connection pipes with the indoor unit firstly and the outdoor unit secondly.
• Be careful in bending the connection pipes, or you will damage the pipes.
• If the tightening torque is too big in tightening the flare nuts, leakage will happen.

ELECTRICAL WIRING

Note: Only an electrician can install the electrical circuit.

1. Open the surface panel.
2. Remove the wiring cover.
3. Route the power connection cord from the back of the indoor unit and pull it toward the

front through the wiring hole for connection.

4. Connect as shown on diagram.
5. Reassemble the wiring cover.

(Fig.2)

Wrenched

Right piping

hole

Left piping
hole

Bent

Flooded

50 mm (2”)

50 mm (2”)