1. When routing the piping and

wiring from the left or right side
of the indoor unit, cut off the tai-
lings from the chassis in neces-
sary (shown in Fig.4, (a), (b) (c)).
(1) Cut off the tailings 1 when
routing the wiring only.
(2) Cut off the tailings 1 and tai-
lings 2 (or tailings 1, tailings 2
and tailings 3) when routing both
the wiring and piping. 1, 2 and 3
in Fig. 4 are the recommended
piping.

2. Wrap the piping and wiring and

pull them through the cut-off-
tailings hole (Shown in Fig. 5).

3. Hang the mounting slots of the

indoor unit on the upper tabs of
the rear panel and check if it is
firm enough. (Shown in Fig. 6).

4. The height of the installed loca-

tion should be 2 m (78-3/4”) or
more from the floor.

Wrapping tape

Connection pipes

Power connection cord

Fig.4

Drainage hose

Right piping

Right rear piping

Left piping

Tailings 3

Tailings 2
Tailings 1

Left rear piping

Fig.5

Fig.6

Fig.7

INSTALLATION INSTRUCTIONS

Installation of the outdoor unit

Install the connection pipe

1. Align the center of the piping flare

with the relevant valve.

2. Screw in the flare nut by hand and

then tighten the nut with spanner and
torque wrench refer to Fig.7.

NOTE: Exceeding tightening torque will
damage the flare surface.

Tightening torque table

Hex nut diameter (mm)

ш 6

ш 12

Tightening torque (N.m)

15 ~ 20

50 ~ 55

Torque wrench

Spanner

Flare
nut

Joint

19