Mds-s50 – Sony MDS-S50 User Manual

Page 20

Advertising
background image

20

MDS-S50

Contents

4-7.

TEST MODE DISPLAYS

Each time the

[LEVEL/DISPLAY/CHAR]

button is pressed, the display changes in the following order.

When CPLAY or CREC are started, the display will forcibly be switched to the error rate display as the initial mode.

1. Mode display
Displays “TEMP ADJUST” (C03), “CPLAY1MODE” (C34), etc.

2. Error rate display
Displays the error rate in the following way.

C =

AD =

)

C = : Indicates the C1 error.
AD = : Indicates ADER.

3. Address display
The address is displayed as follows. (MO: recordable disc, CD: playback only disc)
h =

s =

(MO pit and CD)

h =

a =

(MO groove)

h = : Indicates the header address.
s = : Indicates the SUBQ address.
a = : Indicates the ADIP address.

Note:

“–” is displayed when the address cannot be read.

MEANINGS OF OTHER DISPLAYS

Mode display

Error rate display

Address display

Auto gain display

(Not used in servicing)

Detrack check display

(Not used in servicing)

IVR display

(Not used in servicing)

C1 error and jitter display

(Not used in servicing)

AD error and jitter display

(Not used in servicing)

Servo OFF

Tracking servo ON

Recording mode OFF

CLV normal mode

Tracking offset cancel OFF

Groove

Low reflection

CLV A

CLV UNLOCK

When Off

Display

When Lit

Servo ON

Tracking servo OFF

Recording mode ON

CLV low speed mode

ABCD adjustment completed

Tracking offset cancel ON

Tracking auto gain OK

Focus auto gain OK

Pit

High reflection

CLV S

CLV LOCK

N

X

REC

SYNC

L. SYNC

OVER

B/1

A-/REF

TRACK/LP4

DISC/LP2

SHUF/SLEEP

MONO

Advertising