MDS-S50

5-14. ERROR RATE CHECK

5-14-1. CD Error Rate Check

Procedure:
1. Load the check disc (TDYS-1).
2. Turn the

[ AMS ]

knob to display “CPLAY1MODE”

(C34).

3. Press the

[YES]

button twice and display “CPLAY1MID”.

4. The display changes to “C =

AD =

)”.

5. Check that the C1 error rate is below 20.
6. Press the

[MENU/NO]

button to stop playback, then press

the

Z

button and take out the check disc (TDYS-1).

5-14-2. MO Error Rate Check

Procedure:
1. Load the continuously-recorded disc. (Refer to “5-5. USING

THE CONTINUOUSLY RECORDED DISC” (See page 25))

2. Turn the

[ AMS ]

knob to display “CPLAY1MODE”

(C34).

3. Press the

[YES]

button to display “CPLAY1MID”.

4. The display changes to “C =

AD =

)”.

5. If the C1 error rate is below 20, check that ADER is 00.
6. Press the

[MENU/NO]

button to stop playback, then press

the

Z

button and take out the disc.

5-15. FOCUS BIAS CHECK

Change the focus bias and check the focus tolerance amount.

Procedure:
1. Load the continuously-recorded disc. (Refer to “5-5. USING

THE CONTINUOUSLY RECORDED DISC” (See page 25))

2. Turn the

[ AMS ]

knob to display “CPLAY1MODE”

(C34).

3. Press the

[YES]

button twice to display “CPLAY1MID”.

4. Press the

[MENU/NO]

button when “C =

AD =

)” is

displayed.

5. Turn the

[ AMS ]

knob to display “FBIAS CHECK”

(C16).

6. Press the

[YES]

button to display “

/

c =

T”.

The first four digits indicate the C1 error rate, the two digits
after “/ ” indicate ADER, and the 2 digits after “c =” indicate
the focus bias value.
Check that the C1 error is below 20 and ADER is below 2.

7. Press the

[YES]

button and display “

/

b =

T”.

Check that the C1 error is below 100 and ADER is below 2.

8. Press the

[YES]

button and display “

/

a =

T”.

Check that the C1 error is below 100 and ADER is below 2

9. Press the

[MENU/NO]

button, then press the

Z

button and

take out the disc.

Note:

If the C1 error and ADER are above other than the specified
value at points a (step 8. in the above) or b (step 7. in the above),
the focus bias adjustment may not have been carried out prop-
erly. Adjust perform the beginning again.

5-16. AUTO GAIN CONTROL OUTPUT LEVEL

ADJUSTMENT

Be sure to perform this adjustment when the optical pick-up is
replaced.
If the adjustment results becomes “Adjust NG!”, the optical pick-
up may be faulty or the servo system circuits may be abnormal.

5-16-1. CD Auto Gain Control Output Level Adjustment

Procedure:
1. Load the check disc (TDYS-1).
2. Turn the

[ AMS ]

knob to display “AG Set (CD)” (C11).

3. When the

[YES]

button is pressed, the adjustment will be per-

formed automatically.
“Complete!!” will then be displayed momentarily when the
value is recorded in the non-volatile memory, after which the
display changes to “AG Set (CD)” (C11).

4. Press the

Z

button and take out the check disc (TDYS-1).

5-16-2. MO Auto Gain Control Output Level Adjustment

Procedure:
1. Load the test disc (MDW-74/GA-1).
2. Turn the

[ AMS ]

knob to display “AG Set (MO)” (C10).

3. When the

[YES]

button is pressed, the adjustment will be per-

formed automatically.
“Complete!!” will then be displayed momentarily when the
value is recorded in the non-volatile memory, after which the
display changes to “AG Set (MO)” (C10).

4. Press the

Z

button and take out the test disc

(MDW-74/GA-1).

. >

. >

. >

. >

. >

. >

Advertising