Mds-s50 – Sony MDS-S50 User Manual

Page 24

Advertising
background image

24

MDS-S50

5-2.

PRECAUTIONS FOR CHECKING LASER
DIODE EMISSION

To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.

5-3.

PRECAUTIONS FOR USE OF OPTICAL PICK-
UP (KMS-262B)

As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board when using it.
Before disconnecting the connector, desolder first. Before con-
necting the connector, be careful not to remove the solder. Also
take adequate measures to prevent damage by static electricity.
Handle the flexible board with care as it breaks easily.

Optical pick-up flexible board

5-4. PRECAUTIONS FOR ADJUSTMENTS

1. When replacing the following parts, perform the adjustments

and checks with

in the order shown in the following table.

2. Set the test mode when performing adjustments.

After completing the adjustments, release the test mode.
Perform the adjustments and checks in “Group Service” of the
test mode.

3. Perform the adjustments to be needed in the order shown.
4. Use the following tools and measuring devices.

• Check Disc (TDYS-1) (Part No. : 4-963-646-01)
• Test Disk (MDW-74/GA-1) (Part No. : 4-229-747-01)
• Laser power meter LPM-8001 (Part No. : J-2501-046-A)

or
MD Laser power meter 8010S (Part No. : J-2501-145-A)*

1

• Oscilloscope (Measure after performing CAL of prove.)
• Digital voltmeter
• Thermometer
• Jig for checking BD board waveform

(Part No. : J-2501-196-A)

optical pick-up

flexible board

laser tap

5. When observing several signals on the oscilloscope, etc.,

make sure that VC and ground do not connect inside the oscil-
loscope.
(VC and ground will become short-circuited)

6. Using the above jig enables the waveform to be checked with-

out the need to solder.
(Refer to Servicing Notes on page 8)

7. As the disc used will affect the adjustment results, make sure

that no dusts nor fingerprints are attached to it.

*

1

Laser power meter

When performing laser power checks and adjustment (electrical
adjustment), use of the new MD laser power meter 8010S (Part
No. J-2501-145-A) instead of the conventional laser power me-
ter is convenient.
It sharply reduces the time and trouble to set the laser power
meter sensor onto the objective lens of optical pick-up.

5-7.

Initial setting of adjustment value

5-8.

Recording and displaying of Iop

information

5-9.

Temperature compensation

offset adjustment

5-10. Laser power adjustment

5-11. Iop NV Save

5-12. Traverse adjustment

5-13. Focus bias adjustment

5-16. Auto gain adjustment

5-6-4. Auto Check

Optical

Pick-up

IC101

IC102

IC151

IC190

IC195

D101

Parts to be replaced

Adjustment

Advertising