MDS-S50

5-6-4. Auto Check
(See page 26)

Start

YES

NO

NO

NO

NO

NO

NO

NO

NO

YES

YES

YES

YES

YES

YES

YES

Replace IC195

Replace OP or IC195

Replace IC101, IC195, or D101

5-11. Iop NV SAVE (See page 29)

Replace OP, IC190, or IC195

Replace OP, IC102, IC190,

or IC195

Replace OP, IC101, IC151,

or IC195

Replace OP

Replace the spindle motor

End adjustments

After turning off and then on the power,
initialize the EEPROM
For details, refer to “WHEN MEMORY NG IS DIS-
PLAYED” in 1. SERVICING NOTES (See page 9)

• Abbreviation

OP: optical pick-up

5-7. INITIAL SETTING OF ADJUSTMENT VALUE

(See page 28)

5-9. TEMPERATURE COMPENSATION OFFSET

ADJUSTMENT (See page 28)

5-10. LASER POWER ADJUSTMENT

(See page 28)

5-12. TRAVERSE ADJUSTMENT (See page 29)
5-13. FOCUS BIAS ADJUSTMENT (See page 30)
5-16. AUTO GAIN CONTROL OUTPUT LEVEL

ADJUSTMENT (See page 31)

“op change” in SELF-DIAGNOSIS FUNCTION
(ITEMS OF ERROR HISTORY MODE ITEMS
AND CONTENTS) (See page 3)
5-8. RECORDING AND DISPLAYING THE IOP

INFORMATION (See page 28)

“spdl change” in SELF-DIAGNOSIS FUNCTION
(ITEMS OF ERROR HISTORY MODE ITEMS
AND CONTENTS) (See page 3)