ERVER 6015W-UR/6015W-U/6015W-NTR/6015W-NT User's Manual

Simply push the new power supply module into the power bay until you hear

a click.

Finish by plugging the AC power cord back into the module.

6015W-U/6015W-NT

The SuperServer 6015W-U/6015W-NT has a single 560 watt power supply, which

is auto-switching capable. This enables it to automatically sense and operate with

a 100v - 240v input voltage.

Power Supply Failure

If the power supply module fails, the system will shut down and you will need to

replace the module. Replacements can be ordered directly from Supermicro (see

contact information in the Preface). As there is only one power supply module in the

6015W-U/6015W-NT, power must be completely removed from the server before

removing and replacing the power supply for whatever reason.

Replacing the Power Supply

First turn the power switch on the control panel off, then unplug the power cord

from the system. Replace with the same model (p/n PWS-561-1H20), which can be

ordered directly from Supermicro (see Contact Information in the Preface).

Remove the screws that secure the power supply to the chassis then pull

the module straight out with the handle provided (see Figure 6-6, redundant

power supply server shown). The power supply wiring was designed to de-

tach automatically when the module is pulled from the chassis.

Carefully insert the new power supply into the open bay and push it com-

pletely into the chassis until you hear a clicking sound, meaning it has been

fully inserted.

Secure it to the chassis with the screw you removed previously, then recon-

nect the AC power cord and depress the power button on the control panel to

restart the system.