Write program (com = 14 – Sharp Z-336J User Manual

Page 112

Advertising
background image

9-35

Chapter 9: Message transfers

9

Write program (COM = 14

(H)

)

[Format]

COM

= 14

(H)

PSEG

= Program segment (08

(H)

, 09

(H)

)

See page 9-20.

PADR

L, H

= Program address (0000

(H)

to 7DFF

(H)

)

See page 9-20.

L

L, H

= Data length (number of words)

DATA

1 to N

= Write data (2 bytes = one step)

[Function]
- Write a program with a length (number of words) shown by L, from address PSEG, PADR.
- Up to 512 words can be write at a time.

[Execution condition]
- Write enable mode

: Mode 2

- PC operation status

: Stopping

[Example]
- Write the contents below in program address 000000 to 000002 (file number 8).

Note: Inquiries concerning the bit configuration of programs cannot be accepted.

Ë

Command

Ë

Response

COM

PSEG PADR

L

PADR

H

L

L

L

H

DATA

1

DATA

N

L

H

COM

RSLT PSEG PADR

L

PADR

H

L

L

Top program

address

Top program

address

Address

000000 contents

Address

000001 contents

Address

000002 contents

Ë

Command

Ë

Response

Data length

Data length

14

08

00

00

03

00

00

B8

08

91

00

80

14

00

08

00

00

03

00

Advertising