background image

15-45

Chapter 15: Appendix

15

Assemble the coaxial cable connector

Note: The gap between the center pin and the insulator should not be larger than 1 mm. The insula-

tion material must be intact.

(5) Transceiver

Installing and securing a tap type transceiver

The method and location for installing a transceiver depends on the local conditions. However,
common installation locations are as follows.

Install on a wall
Install in the free access space under the floor
Install in the ceiling or in a cable rack
Install near a station

The precautions when installing a transceiver are as follows:

Secure the transceiver on the floor or a flat surface using foot, or secure it using self-tapping

screws.

When installing a transceiver in the ceiling or below the floor, select a location that is easy to

access for maintenance and checking.

The installation distance between transceivers is 2.5 m. (Use the markers on the cable that are

spaced every 2.5 m)