background image

9-38

Chapter 9: Message transfers

9

Read time (COM = A3

(H)

)

[Format]

COM

= A3

(H)

H

= Hour

(00

(H)

to 23

(H)

: BCD)

M

= Minute

(00

(H)

to 59

(H)

: BCD)

S

= Second

(00

(H)

to 59

(H)

: BCD)

[Function]
- Read time data.

[Execution condition]
- Write enable mode

: Mode 0, mode 1 and mode 2

- PC operation status

: Stopping, operating

[Example]
- Read time data.

COM

Ë

Command

Ë

Response

COM

RSLT

H

M

S

A3

21 o’clock 12 minutes 37 seconds

Ë

Command

Ë

Response

A3

00

21

12

37

Advertising