6

[4] Connection of JW-50FL

(1) Connection of 10BASE5

This paragraph describes how to connect 10BASE5 cable to the JW-50FL.

Connecting the transceiver cable

1

Slide the lock on the 10BASE5 connector (on the JW-50FL) up.

2

Insert the connector so that the two locking posts on the cable connector match the holes on

the slide lock.

3

Slide the lock down to lock the cable connector.

Wiring the power source

When a 10BASE5 is used, 12 VDC power should be supplied to the transceiver.
Supply power to the 12 VDC power terminals using a commercial constant voltage power supply
unit.

Remarks

- Use a power supply that is dedicated for use by the JW-50FL.
- Do not reverse the positive and negative connections to the power terminals. Reversing the

polarity may damage the JW-50FL.

Locking post

Transceiver cable

Slide lock

10BASE5 connector

Locking post

12 VDC

* Fuse (0.6 A)

Black wire (-)

Red wire (+)

Twisted pair wires

Case

Green wire

(ground)

Cable

(Accessory: Connector, cable length 1.5 m)

* Use a fuse melt with time lag

Item

Specifications

Supply voltage

Current capacity

12 VDC

5%

0.5 A minimum.