8-3 Parameter settings for cyclic transfers

The parameters related to cyclic transfers are as follows.

Corresponds to

1

to

6

on page 8-1.

(For parameter details

See Chapter 12.)

- Enter the top address in word units (* above).

Pages 8-8 to 8-12.

Ex.: Enter 1600 to 1601 (word address 01C0

(H)

) as the top address at parameter addresses 10

and 11

(8)

.

Parameter

address

(8)

Description

2

10

Top address (word address) of the data sending areas of own node area 1 *
- Address 10 is for the lower digit and 11 is for the upper digit.

11

3

12

Sending data length (word) of own node area 1
- Address 12 is for the lower digit and 13 is for the upper digit.

13

5

14

Top address (word address) of the data sending areas of own node area 1 *
- Address 14 is for the lower digit and 15 is for the upper digit.

15

6

16

Sending data length (word) of own node area 1
- Address 16 is for the lower digit and 17 is for the upper digit.

17

1

20

Top address (word address) of area 1 on a PC *
- Address 20 is for the lower digit and 21 is for the upper digit.

21

22

File number of area 1 on the PC.

4

24

Top address (word address) of area 2 on a PC *
- Address 24 is for the lower digit and 25 is for the upper digit.

25

26

File number of area 2 on the PC.

Parameter address

(Upper digit) 11

(Lower digit) 10

Set value (HEX)

01

C0