11 technical specifications, B3l−54 – Siemens CP 343-1 User Manual

Page 54

Advertising
background image

11 Technical Specifications

B3L−54

CP 343-1 Lean for Industrial Ethernet / Manual Part B3L

Release 03/2007

C79000-G8976-C198-04

11 Technical Specifications

Transmission rate

10 Mbps and 100 Mbps

Interfaces
Connection to Ethernet

2 x RJ−45 jack

Power supply

DC +24 V (permitted range: +20.4 V through +28.8

V)

Current consumption

S

from backplane bus

S

from external 24 V DC

200 mA maximum

TP: approx. 0.2 A maximum

Power loss approx.

5.8 W

Permitted ambient conditions

S

Operating temperature

S

Transportation/storage

temperature

S

Relative humidity max.

S

Altitude

0 °C to +60 °C

−40 °C to +70 °C

95% at +25 °C

up to 2000 m above sea level

Design

S

Module format

S

Dimensions (W x H x D) in mm

S

Weight approx.

Compact module S7-300; single width

40 x 125 x 120

220 g

Table 11-1 Description of the Approvals

c−UL−us

UL 508
CSA C22.2 No. 142

c−UL−us for hazardous locations

UL 1604, UL 2279PT.15
CL. 1, Div. 2 GP.A.B.C.D T..
CL. 1, Zone 2, GP. IIC, T..
CL. 1, Zone 2, AEx nC IIC T..

FM

FM 3611
CL. 1, Div. 2 GP.A.B.C.D T..
CL. 1, Zone 2, GP.IIC. T..
Ta:..

C−TICK

AS/NZS 2064 (Class A).

CE

EN 61000−6−2, EN 61000−6−4 (replaces EN

50081−2)

ATEX Zone 2

EN60079−15
II 3 G EEx nA II T..
KEMA 03 ATEX 1228 X

Temperature code “T..” and maximum ambient temperature “Ta:..” as listed on the type plate

Advertising