13

·

18

16 points output

32 points output

64 points output

(JW-62SC)

Vacant slot 00

Lower bits are dummy I/O points

16 points output

32 points output

64 points output

(JW-64NC)

Special I/O module

Special I/O module

• Use addresses 000101 to 000137

(8)

listed below when the I/Os are the JW type, and the register module

type and number of dummy I/O points can be set using the arbitrary I/O registration mode.

If ZW type I/Os are used, no setting is required.

• Initial value of the address 000100 to 000137

(8)

are all 00

(H)

.

JW-12S, JW-13S,
JW-32S

JW-32SC, JW-33S,
JW-34S, JW-35S

JW-11N, JW-12N,
JW-13N

JW-31N, JW-32N,
JW-34N, JW-34NC

JW-2DA, JW-8AD,
JW-31LM

JW-2HC,
JW-11DU/12DU

000100

(2/3)

Address

(8)

Set contents

Setting method (value)

91

(H)

92

(H)

94

(H)

00

(H)

A1

(H)

A2

(H)

A4

(H)

D1

(H)

F1

(H)

Set kinds of I/O module

Rack number: 0

Slot number: 0

• Set 1 slot

• Set only in case of manual I/O

registration

• For address 000100

(8)

, set 00

(H)

JW-I/O ZW-I/O

000101

000102

000103

000104

000105

000106

000107

000110

000111

000112

000113

000114

000115

000116

000117

Set contents

Set kinds of I/O module
Rack number: 0
Slot number: 1
• For address 000100

(8)

, set 00

(H)

(Setting method is same as 000100)

Address

(8)

Rack number: 0, Slot number: 2

Rack number: 0, Slot number: 3

Rack number: 0, Slot number: 4

Rack number: 0, Slot number: 5

Rack number: 0, Slot number: 6

Rack number: 0, Slot number: 7

Rack number: 0, Slot number: 8

Rack number: 0, Slot number: 9

Rack number: 0, Slot number: A

Rack number: 0, Slot number: B

Rack number: 0, Slot number: C

Rack number: 0, Slot number: D

Rack number: 0, Slot number: E

Rack number: 0, Slot number: F

Rack number: 0, Slot number: 1

Rack number: 0, Slot number: 2

Rack number: 0, Slot number: 3

Rack number: 0, Slot number: 4

Rack number: 0, Slot number: 5

Rack number: 0, Slot number: 6

Rack number: 0, Slot number: 7

Rack number: 0, Slot number: 8

Rack number: 0, Slot number: 9

Rack number: 0, Slot number: A

Rack number: 0, Slot number: B

Rack number: 0, Slot number: C

Rack number: 0, Slot number: D

Rack number: 0, Slot number: E

Rack number: 0, Slot number: F

000120

000121

000122

000123

000124

000125

000126

000137

000130

000131

000132

000133

000134

000135

000136

000137

Set kinds of I/O module