Installation 2 – Speco Technologies SIPSD37X User Manual

Page 17

Advertising
background image

37X Speed Dome Camera

17/50

‰

Video

z

Use BNC coaxial cable only.

‰

Alarm Input

Before connecting sensors, check driving voltages and output signal types of the sensors.

Since output signal types of the sensors are divided into Open Collector type and

Voltage Output type in general, the wiring must be done properly after considering

those types.

Signal

Description

IN COM+

The electric power source to drive input circuit. Connect the (+) wire of electric

power source to drive the Sensors to this port as shown in the above circuit.

IN1 -, IN2 -, IN3 -

Connect the outputs of sensors to each port as shown in the above

circuit.


If you want to use Alarm Input, the types of sensors must be selected in OSD menu. The

sensor types are divided into Normal Open and Normal Close. If wrong sensor types are

selected, alarms should be activated reversely to sensor inputs.

~

Normal Open Output Voltage is high state when sensor is activated

~

Normal Close Output Voltage is high state when sensor is not activated


‰

Relay Output

Internal

OUT 1

AC or DC

LOAD

The maximum loads are as follows.

Power Type

DC Power

AC Power

Maximum Load

MAX. 24VDC, 1A

MAX. 125VAC, 0.5A

IN COM+

+5V~12V

IN 1-

IN 3-

+

+

-

-

+

-

Internal

Sensor 1

Sensor 3