Sierra INNOVA 215 User Manual

Page 32

Advertising
background image

IM-215 Rev-A.1 Series Innova-Switch™ Page 32 of 42

7.0

SPECIFICATIONS


TYPE:

Thermal Differential-Dual RTD Sensors


PROCESS CONNECTIONS:

0.75” (19.05mm) MNPT Standard, 0.5"(12.7mm), 1"
(25.4mm) MNPT, and various flanges optional.


INSERTION LENGTH:

Two inch (50.8mm) Standard, (shorter 0.5 inch (12.7mm)
and longer to 120 inch (3048mm) optional).


CONSTRUCTION MATERIALS:

Wetted parts are 316L SS welded construction (alternate
materials for corrosive environments available as
options. Consult factory.)


AGENCY INSTRUMENT RATINGS: CSA Explosion Proof: (CS series) T4A

Class I, Group B, C, and D

Class II, Group E, F, and G

CENELEC/Explosion Proof (CN Series):

EEx d IIC T4(Akron Electric Enclosure)

EEx d IIB T4(Killark Enclosure)

CE: EMC Directive: 89/336/EEC (CE Option)


OPERATING TEMPERATURE:

Process: -70°C to + 200°C (-100°F to +390°F) standard

(to + 600°C (+1000°F) optional

Electronics: -40°C to +60°C (-40°F to +140°F)


PRESSURE RATED:

To 3000 psig (20.4 MPa)


RANGE

Gaseous Mass Flow: 0.1 to 500 fps

Liquid Mass Flow: 0.01 to 5 fps


REPEATABILITY:

± 1% of Set Point or ± 1/32 inch (±.8mm)


TIME RESPONSE:

0.5 to 10 seconds no-flow (dry) to flow (wet) and 2 to 60
seconds flow (wet) to no-flow (dry) (application
dependent)


INPUT POWER:

115 Vac, 50/60HZ standard. (230 Vac, 50/60HZ, 24 Vdc,
or 24 Vac optional); 3.1w. maximum.


SIERRA INSTRUMENTS PART NO.


FUSE REQUIREMENTS (F1):

CSA/FM

CENELEC

115 Vac: 1/4 amp

101603

101605

230 Vac: 1/4 amp

101603

101605

24 Vdc: 1/4 amp

101603

101605


OUTPUT:

5A, 250 VAC, DPDT Standard (Optional 10A, 250 Vac
SPDT) 5A 30 VDC


STABILITY:

Temperature compensated over entire range.

Advertising