designed for pollution degree 1 (P1) as per EN61558-1, which is defined as “No pollution or only dry

non-conductive pollution.”

Electrostatic discharge (ESD)

SMART Response components meet the requirements of EN61000-4-2 severity level 4 for direct and

indirect ESD. No malfunction or damage up to 15 kV (both polarities) with a 330 ohm, 150 pF probe

(air discharge). Unmated connectors meet 8 kV for direct (contact) discharge.

Conducted and radiated emissions

SMART Response hardware’s narrowband radiated electric field meets the limits for Class B

performance, as defined in EN55022/CISPR 22.

Computer requirements

Windows operating systems

l

Pentium® 4 or later processor

l

512 MB of RAM (1 GB recommended)

l

Free hard disk space:

Software

Space required

SMART Notebook software

277 MB

___

Gallery Essentials

549 MB

___

Lesson Activity Toolkit

111 MB

SMART Product Drivers

145 MB

SMART Response assessment software

47 MB

SMART Sync™ Teacher software

37 MB

Common platform

62 MB

Total

1228 MB

l

Windows® XP SP3, Windows Vista® SP2 or Windows 7 operating system

l

Internet Explorer® Internet browser 6.0 or later

l

Adobe® Flash® Player 10 Firefox® plug-in

l

Adobe Flash Player 10 ActiveX® control for SMART Notebook software