Simrad Autopilot AP26 User Manual

Page 122

Advertising
background image

Simrad AP26 and AP27 Autopilots

120

20221586B

Display readout Probable fault

Recommended action

Rudder test failed Following conditions

may exist:
a) Rudder feedback

failure

b) Autopilot

Computer current
overload

c) Bypass/clutch

overload

Refer to recommended actions for
the specific probable faults.

Rudder moves in only
one direction

a) Poor connection to

one of the
solenoids
(continuously
running pump)

b) Faulty Power PCB

in autopilot
computer

a) Check the connections
b) Replace the Autopilot Computer

Power PCB

Rudder test not
completed within 2
min.
a) Poor connections

to the drive unit

b) Faulty Main PCB

in the Autopilot
Computer

c) Faulty Power PCB

in the Autopilot
Computer

a) Check connections
b) Replace the Main PCB
c) Check the Power PCB for traces

of burned transistors. – Change
Power PCB.

Rudder moves at full
speed to one side.
a) Faulty Power PCB

in Autopilot
Computer

Replace Autopilot Computer Power
PCB

Advertising
This manual is related to the following products: