Installation

20221586B

67

RATE

COMPASS

AP16, AP25, AP26

Figure 3-13 RC36 connection to autopilot control unit

Plug the RC36 into a Robnet2 connector (see Figure 3-9) or cut
the connector from the cable and connect the wires in parallel
with the cable shown in Figure 3-11.

3.14 RFC35 Fluxgate Compass installation

(Optional back-up)
The RFC35 Fluxgate Compass is a magnetic sensor, which
means you have to take the same precautions at installation as
for the standard RC36 (see previous page).
• Connect the RFC35 to the autopilot computer as per Figure

3-14.

RFC35

FLUXGATE

COMPASS

AUTOPILOT COMPUTER

MAIN PCB

Heading

Sensor

*

* NON POLARIZED

(COLOR INDEPENDENT)

HS
+

HS-

Figure 3-14 RFC35 connection

Advertising