Installation, 59 linear drive units – Simrad Autopilot AP26 User Manual

Page 61

Advertising
background image

Installation

20221586B

59

LINEAR DRIVE UNITS

MODEL MOTOR

VOLTS

AUTO-

PILOT

COM-

PUTER

MAX

STROKE

mm (in.)

PEAK

THRUST

kg (lb.)

MAX

RUDDER

TORQUE

Nm

(lb.in.)

HARD-

OVER

TIME

sec.

(30% load)

PWR.
CON-

SUMP.

TILLER

ARM

mm

(in.)

MLD200 12V

AC10

300

(11,8)

200

(440)

490

(4350)

15 1,5-6

A

263

(10,4)

HLD350 12V

AC10

200

(7,9)

350

(770)

610

(5400)

12 2,5-8

A

175

(6,9)

HLD2000L 12V

AC20

340

(13,4)

500

(1100)

1460 (12850)

19

3-10 A

298

(11,7)

HLD2000D 24V AC20

200

(7,9) 1050

(2310)

1800

(15900)

11 3-10

A

175

(6,9)

HLD2000LD 24V AC20

340

(13,4) 1050

(2310)

3180

(28000)

19 3-10

A

298

(11,7)

MSD50* 12V

AC10

190

(7,5)

60

(132)

– 15

0,8-2

A

Steering gear interface: Connects to quadrant or tiller.
* For stern drive power assisted steering only.

1. The motor voltage is stepped down by the autopilot computer

when operating from 24V or 32V mains.

2. The specified autopilot computer is necessary to achieve max

drive unit capacity.

3. Recommended operational thrust or torque is 70% of listed

peak value.

4. Typical average power consumption is 40% of listed

maximum value.

Advertising
This manual is related to the following products: