Ap27 connection, Rc36 rate compass installation, 13 rc36 rate compass installation – Simrad Autopilot AP26 User Manual

Page 67: Installation

Advertising
background image

Installation

20221586B

65

On-

O

ff

Vs
ys

+

AUTOPILOT COMPUTER

MAIN PCB

ROBNET

Bu
s+

Vs
ys

Wh

Bn

Bu
s

Pnk Gry Yel

AP26

CONTROL UNIT

REAR VIEW

TB15

Figure 3-11 Control unit connection

J1 and J2 (left) are Robnet2 connectors. J3 and J4 are SimNet
connectors.

AP27 connection

If a Simrad AP27 is part of the system, use the Robnet2
connector in a free receptacle (see Figure 3-9). Alternatively cut
the connector from the cable and connect the wires in parallel
with the cable shown on Figure 3-11 using the same colour code.

Note !

The AP27 cable contains an air-breathing tube. Check that the
tube is open after you have cut the cable.

3.13 RC36 Rate Compass installation

Figure 3-12

RC36 mounting

The heading sensor is the most important part of the autopilot
system and great care should be taken when deciding the

Advertising