Timing engine, Main settings – Symmetricom S100 User Manual

Page 73

Advertising
background image

S100 User Guide – Rev. D – June 2005

65

2

5

3

Alternatively, you can use Paste Certificate to copy and paste the certificate from the

certreq.jsp

file into this field. Open the

certreq.jsp

file using a text editor (e.g., Notepad)

and copy the contents. The certificate should be base 64 encoded. Paste the contents in the
Paste Certificate field here, then click

Submit.

The S100 is self-signed, thus it can verify your certificate.

For more about how the S100 uses NTP keys and certificates, see

“S100 and NTP v4’s

Security Features” on page 10

.

Timing Engine

This section of the interface lets you view various aspects of the Symmetricom bc635/637
PCI board—the timing engine of the S100.

Main Settings

The timing engine mode choices you see in the drop-down list box are:

• GPS is the default, which obtains the time from GPS receiver and antenna.

• IRIG, which obtains the time from the IRIG time code input. (Note: IRIG time code

doesn’t include the year with its time information. Be sure to enter the year in the Year
field.)

• Free Running means there is no external timing source used, that the time is set

manually

• One Pulse Per Second, or 1PPS, syncs the oscillator to a user-supplied 1PPS

Figure 4-12: Timing Engine Main Settings