M O D E L O P T I O N S

Model I601R
914 mm
All Refrigerator

Model I601RG
914 mm
All Refrigerator
with Glass Door

Model I601F
914 mm
All Freezer

Model I611
762 mm
Over-and-Under

Model I611G
762 mm
Over-and-Under
with Glass Door

Model I650
914 mm
Over-and-Under

Model I650G
914 mm
Over-and-Under
with Glass Door

Model I661
914 mm
Side-by-Side

Model I642
1067 mm
Side-by-Side

Model I685
1067 mm
Side-by-Side
Ice | Water Dispensing

Model I632
1219 mm
Side-by-Side

Model I695
1219 mm
Side-by-Side
Ice | Water Dispensing

Model ICB648PRO
1219 mm
Side-by-Side
Built-In or Free-Standing

Model ICB648PROG
1219 mm
Side-by-Side
with Glass Door
Built-In or Free-Standing

P L A N N I N G I N F O R M A T I O N

Although the Sub-Zero Built-In line offers a wide

range of designs and configurations, the basic

planning considerations for all models have

much in common. As you integrate Built-In

models into your overall plan, review installation

requirements for your particular model(s). The

Installation Specifications illustrations provide

planning information for all Built-In models—

overlay and stainless steel.

Allow the door(s) to open a minimum of 90˚ or

you‘ll have problems removing drawers. With the

door opening at 90˚, you may have to move

drawers slightly to clear the door interior.

For corner installations, allow for a minimum

76 mm filler so that the door can open to 90˚.

If you‘re using raised panels, consider using a

wider filler.

When units are installed side by side, a filler strip

is recommended. The width of this filler strip will

vary depending on the configuration and panels

you use.

Be sure to add the filler strip width to your

finished rough opening dimension. In any

installation of two units side by side without a

filler strip, add an additional 13 mm to your

combined numbers. This will allow for the

proper width.

IMPORTANT NOTE: Refer to the full-scale illus-

trations at the end of this section for specifics

on door openings and filler size alternatives.

E L E C T R I C A L R E Q U I R E M E N T S

International models from the factory designed

without a transformer require a 220/240 V AC,

50/60 Hz electrical supply, fused at the correct

rating for the unit. If required by local or national

codes, the power cord can be easily replaced

using the power inlet device.

International models using a factory installed

transformer require a 220/240 V AC, 50/60 Hz

electrical supply, fused at the correct rating for

the unit. These models will come equipped with

Schuko power cords. The power cord may need

to be replaced depending on local and national

codes. The USA power cord that is supplied

with the product must be disconnected with the

appropriate transformer output to be connected

in its place.

IMPORTANT NOTE: The electrical outlet must

be grounded. The outlet must be flush with the

back wall. Refer to the Installation Specifications

illustration for your model for exact placement.

IMPORTANT NOTE: A ground fault circuit

interrupter (GFCI) is not recommended and may

cause interruption of operation.

P L U M B I N G C O N S I D E R A T I O N S

For Built-In models with an automatic ice maker,

rough in the water supply line. Connect a

6.35 mm OD copper line to the house supply,

being sure to use an easily accessible shut-off

valve between the supply and the refrigerator.

Do not use self-piercing valves. A saddle valve kit

(4200880) is available from your Sub-Zero dealer.

For Built-In models, a line filter is required when

water conditions have a high sediment content.

The ice maker operates on water pressure of 1.4

bar to 6.9 bar.

IMPORTANT NOTE: In some cases a reverse

osmosis water filter system may not be able to

maintain the minimum water pressure consistently.

IMPORTANT NOTE: A reverse osmosis system

can be used with Models ICB648PRO and

ICB648PROG, provided there is constant water

pressure of 1.4 bar to 8.3 bar supplied to the

unit at all times.

The water line should be routed up through the

floor within 13 mm from the back wall and no

higher than 76 mm off the floor. If you have to

come through the wall, make sure the water line

is no more than 76 mm from the floor.

Regardless of the routing, allow 1 m of excess

copper tubing to remain outside the wall or floor

for easy connection to the unit. Refer to Installa-

tion Specification illustrations.