P L A N N I N G I N F O R M A T I O N

Before moving the Integrated unit into place, be

sure that the finished opening dimensions, elec-

trical and plumbing locations and minimum door

and drawer clearances are accurate. Refer to the

Installation Specifications illustration for your

model on the following pages. Be sure your

installer has this information before finishing

work is completed.

Integrated models without an automatic ice

maker will not require the plumbing connections

shown in the illustrations.

The height of the tall unit is set at 2032 mm.

You can allow the top of the door panel to

exceed this dimension with caution. If you are

working with 2134 mm or 2438 mm neighboring

panels, you can utilize door panels to match this

height. Other critical dimensions regarding the

door swing, drawer openings and toe kick clear-

ance are noted in the Overall Dimensions illustra-

tions on the following pages. Also refer to the

full-scale illustrations at the end of this section

for specifics on door openings and other specifi-

cations.

IMPORTANT NOTE: The anti-tip bracket must be

installed to prevent the unit from tipping

forward.

E L E C T R I C A L R E Q U I R E M E N T S

International models from the factory designed

without a transformer require a 220/240 V AC,

50/60 Hz electrical supply, fused at the correct

rating for the unit. If required by local or national

codes, the power cord can be easily replaced

using the power inlet device.

International models using a factory installed

transformer require a 220/240 V AC, 50/60 Hz

electrical supply, fused at the correct rating for

the unit. These models will come equipped with

Schuko power cords. The power cord may need

to be replaced depending on local and national

codes. The USA power cord that is supplied

with the product must be disconnected with the

appropriate transformer output to be connected

in its place.

IMPORTANT NOTE: The electrical outlet must

be grounded. The outlet must be flush with the

back wall. Refer to the Installation Specifications

illustration for your model for exact placement.

IMPORTANT NOTE: A ground fault circuit

interrupter (GFCI) is not recommended and may

cause interruption of operation.

32

Do not use an extension cord or 2-prong

adapter. Electrical ground is required.

Do not under any circumstances remove

the power supply cord ground prong.

P L U M B I N G C O N S I D E R A T I O N S

For models with an automatic ice maker, rough

in the water supply line. Connect a 6.35 mm OD

copper line to the house supply, being sure to

use an easily accessible shut-off valve between

the supply and the unit. This shut-off valve

should not be installed behind the unit.

Do not use self-piercing valves. A saddle valve

kit (4200880) is available from your Sub-Zero

dealer. An in-line filter is required when water

conditions have a high sediment content. The ice

maker operates on constant water pressure

between 1.4 bar and 6.9 bar.

IMPORTANT NOTE: In some cases, a reverse

osmosis water filter system may not be able to

maintain the minimum pressure consistently.

The Installation Specifications illustration for

your model on the following pages shows the

precise placement of the water line. When

routing the water through the side walls, you

must place the water line within 13 mm of the

floor and as close as possible to the back wall.

The line must be routed around the anti-tip

bracket so it clears the bracket and the leveling

feet of the unit as shown in the top view of the

illustration. Regardless of the routing, allow for

686 mm of excess copper tubing to remain

outside the wall or floor for easy connection to

the unit.

IMPORTANT NOTE: Do not route water supply

line in front of the compressor tray. The tray

must be slid forward for service.

I N S T A L L A T I O N

Refer to the
installation instruc-
tions shipped with
each Sub-Zero
product for detailed
specifications.