I N S T A L L A T I O N O P T I O N S

The illustrations show some typical installations

and their dimension considerations. The depth

dimension in the illustrations may vary depend-

ing on cabinet styles, treatment of countertops

or other design options.

IMPORTANT NOTE: The depth of each

Integrated model is 610 mm from the front of

the unit to its back. Your design may necessitate

moving the unit back or cabinets forward to

achieve a flush fit. This will require a minimum

rough opening depth of 635 mm. Refer to the

illustrations.

NOTE: In the Installation Options illustrations,

the first width dimension shown is for 686 mm

wide units and the second dimension is for 914

mm wide units.

D U A L I N S T A L L A T I O N S

If two or more Integrated models are installed

side by side where there is 51 mm or less of

space between the units, a heater kit is recom-

mended—TTDUAL for two tall units installed side

by side and BBDUAL for two base units or a

base unit and a tall unit installed side by side.

These optional components are available through

your Sub-Zero dealer.

TOP VIEW

CABINETS

635

mm

686 mm

914 mm

OR

Installation without side panels

Installation with side panels

Installation of two units side by side

Installation at end of run

MINIMUM 16 mm SIDE PANELS

CABINETS

OR

635

mm

686 mm

914 mm

TOP VIEW

CABINETS

OR

635

mm

1372 mm

1829 mm

MINIMUM 16 mm SIDE PANELS

CABINETS

OR

635

mm

686 mm

914 mm

A C C E S S O R I E S

Optional accessories
are available
through your
Sub-Zero dealer.