Illustration 8 shows how you can box out a

landing space for the bezel using stiles and rails

to create this space. Again, keep in mind, that

the total thickness of the panel at this level must

not exceed 29 mm.

O V E R L A Y P A N E L G R I L L E

Overlay grille panels for the panel grille match

the design of the door panels. Overlay units,

except Models I601R, I601RG and I601F, come

standard with an 279 mm panel grille. Optional

grilles are available in 25 mm height increments

from 254 mm to 381 mm. Overlay grille panel

specifications for the panel grille are listed on

page 23. Also refer to illustration 4 on page 19

for additional overlay panel dimensions.

Do not exceed the panel dimensions listed

for the appropriate overlay grille panel you

are specifying. The decorative panel cannot

be any larger or it may restrict the airflow

to the compressor area and cause problems

with the operation of the Sub-Zero unit.

O V E R L A Y D O O R P A N E L S

For glass door Models I601RG, I611G and I650G,

the refrigerator door panel must include a cut-

out to accommodate the window. Refer to the

Overlay Panel Specifications for Models I601RG,

I611G and I650G on page 22.

IMPORTANT NOTE: On glass door models, the

glass portion of the door must be exposed and

not covered by any part of the panel.

For Models I685 and I695, the refrigerator door

panel must include a cut-out to accommodate

the glasswell and bezel. The thickness of the

panel in this area can range from 6 mm to a

maximum of 29 mm.

IMPORTANT NOTE: Regardless of the thickness

of the overlay panel for Model I685 or I695, you

must plan for a flat ’landing’ space for the

decorative bezel surrounding the glasswell area.

Refer to page 23 for exact cut-out dimensions of

the glasswell area in the overlay, spacer and

backer panels. This ’landing’ area can be accom-

plished in a number of different ways. We are

showing two in Illustrations 7 and 8 below.

Illustration 7 shows how you can recess the

bezel to the inset panel. You must rout out a

space to accommodate the 327 mm height of

the bezel. Also keep in mind that the amount of

material you will rout out of the stile will vary

because of the thickness of this element.

However, the width of the stile immediately

adjacent to the bezel must be 37 mm. DO NOT

cut the entire stile to this dimension. In this illus-

tration you can see that rails above and below

the bezel give this a finished look. Make sure

that the bezel is not supporting weight from

the panel.

I N S T A L L A T I O N

To install overlay
panels, see the
detailed procedures
outlined in the
Sub-Zero Built-In
Installation Guide.

43 mm

Edge of

Panel to

Cut-Out

Glasswell

Cut-Out

37 mm

Width

of Stile

Adjacent

to Bezel

Routing

Required

327
mm

Height

of Bezel

Illus. 8

Illus. 7