P A N E L C O N S I D E R A T I O N S

The illustrations below provide panel width

dimensions for installation of a single tall unit,

686 mm and 914 mm wide models.

Illustrations on the following page provide panel

width dimensions for installing two tall units

side by side, 686 mm wide models and 914 mm

wide models.

679 mm

APPLIANCE

DOOR WIDTH

SUB-ZERO

UNIT

TO BACK

OF UNIT

657 mm

686 mm

CABINETRY

OR SIDE

PANEL

CABINETRY

OR SIDE

PANEL

REVEAL

REVEAL

*SUBTRACT PANEL WIDTH FROM CABINETRY OPENING TO DETERMINE ACTUAL WIDTH OF REVEAL

635 mm

635 mm

610 mm

19 mm

PANEL

3 mm* min

3 mm* min

908 mm

APPLIANCE

DOOR WIDTH

SUB-ZERO

UNIT

TO BACK

OF UNIT

886 mm

CABINETRY

OR SIDE

PANEL

CABINETRY

OR SIDE

PANEL

*SUBTRACT PANEL WIDTH FROM CABINETRY OPENING TO DETERMINE ACTUAL WIDTH OF REVEAL

914 mm

635 mm

635 mm

REVEAL

3 mm* min

REVEAL

3 mm* min

19 mm

PANEL

610 mm

IMPORTANT NOTE: The depth of each

Integrated model is 610 mm from the front of

the unit to its back. You must allow for the

thickness of the panel you are applying when

planning for the finished rough opening depth if

you want the front panel to be flush with

surrounding cabinetry. You may have to move

the unit back into drywall or bring the cabinets

forward to achieve a flush fit.

9 1 4 m m

W I D E M O D E L S

Panel width dimen-
sions for installation
of a 914 mm wide
tall unit.

Dimensions are based
on a 3 mm reveal. A
reveal of up to 6 mm
is possible, but panel
dimensions need to be
adjusted accordingly.

6 8 6 m m

W I D E M O D E L S

Panel width dimen-
sions for installation
of a 686 mm wide
tall unit.

Dimensions are based
on a 3 mm reveal. A
reveal of up to 6 mm
is possible, but panel
dimensions need to be
adjusted accordingly.

I N S T A L L A T I O N

To install integrated
panels, see the
detailed procedures
outlined in the
Sub-Zero Integrated
Installation Guide.

Advertising