Buzzer output, E-mail notification, Settings – Samsung SHR-1041 User Manual

Page 38

Advertising
background image

_

settings

settings

Buzzer output

In the <system setup> window, use the direction
buttons ($%_+/ENTER) to select <event/sensor>.
Select <Buzzer output> and use the direction buttons
($%_+/ENTER) to select and set a desired item.

operation : Set the operation of the buzzer output.
- n/o(Normal Open): Sensor is open in normal condition,

it generates alarm if the sensor is closed.

hdd event : Set the buzzer output if a HDD event
occurs.
mode : Set the output mode of the buzzer.
- If set to <Latched>, the buzzer will sound for as much time as defi ned in DURATION.
- If set to <transparent>, the DURATION item will be disabled.
duration : Set the duration of the buzzer output.
- If you select <until>, the buzzer will be stopped when you press any button on the front panel or the

remote control.

aLarm, video Loss, motion : Set the buzzer output for each channel if an event of alarm, video
loss or motion detection occurs.

When your settings are completed, click <appLy> on the bottom.
Your settings will be applied.

e-maiL notiFication

In the <system setup> window, use the direction
buttons ($%_+/ENTER) to select <event/sensor>.
Select <e-maiL notiFication> and use the direction
buttons ($%_+/ENTER) to select and set a desired item.

notiFication : Turn on or off the notifi cation of an
event if it occurs.
- If set to <on>, the applicable menu is activated where

you can set other options.

- If set to <oFF>, other items will be disabled.
hdd event : Turn on or off the notifi cation of a HDD
event if it occurs.
Booting event : Turn on or off the notifi cation of an email when the system boots.
aLarm, video Loss, motion : Set the event notifi cation for each channel if an event occurs such
as alarm, video loss or motion detection.
FreQuency : Set the notifi cation interval for events occurred. (10MIN~30MIN, Default: 30MIN)

When your settings are completed, click <appLy> on the bottom.
Your settings will be applied.
When done, if you want to move to the previous menu, press the [return] button on the front panel or
the remote control, or click <

CAM1

CAM1

CAM1

CAM1

> on the top right corner.

A photo taken in a low contrast scene naturally causes a lot of noise, and often occurs an unnecessary motion event,
which may cause damage to the camera set. In such case, set a function of E-MAIL NOTIFICATION to OFF, or set
FREQUENCY to a longer time (ex: 30 MIN).
You are recommended to use a night vision camera in a low contrast scene.

.

.

.

.

.


.

.

M

CAM1

CAM1

CAM1

CAM1

EVENT/SENSOR

HDD

EVENT

ALARM

INPUT

APPLY

UNDO

ALARM

OUTPUT

BUZZER

OUTPUT

E-MAIL

NOTIFICATION

ALARM

1
2
3
4

OFF

ON

VIDEO LOSS

MOTION

FREQUENCY

5 MIN

ON

NOTIFICATION
HDD EVENT
BOOTING EVENT

CAM1

CAM1

CAM1

CAM1

EVENT/SENSOR

HDD

EVENT

ALARM

INPUT

APPLY

UNDO

ALARM

OUTPUT

BUZZER

OUTPUT

E-MAIL

NOTIFICATION

ALARM

DISABLE

1
2
3
4

OPERATION
MODE

LATCHED

ON

HDD EVENT
DURATION

5 SEC

VIDEO LOSS

MOTION

02235A_SHR-1041K_ENG.indb 38

2009-02-17 오전 10:51:07

Advertising