4

SEMS screw (M4 x 0 mm)

Panel holder

Base stand

Operation panel

Note: If you use the transceiver for a long period when the vehicle battery is not fully charged

or when the engine is OFF, the battery may become discharged and will not have sufficient

reserves to start the vehicle. Avoid using the transceiver under these conditions.

1 Route the DC power cable supplied with the transceiver directly to the

vehicle’s battery terminals using the shortest path from the transceiver.

• When using a noise filter, it should be installed with an insulator to prevent it from

touching metal on the vehicle.

• We do not recommend using a cigarette lighter socket as some cigarette lighter

sockets introduce an unacceptable voltage drop.

• If the power cable must be routed through a hole in the vehicle chassis or body,

for example in the fire wall at the front of the passenger compartment, use a

rubber grommet to protect the cable from abrasion. Dismantle the fuse holder to

pass the cable through the fire wall.

• The entire length of the cable must be dressed so it is isolated from heat,

moisture, and the engine secondary (high voltage) ignition system/ cables.

2 After the cable is in place, wind heat-resistant tape around the fuse holder

to protect it from moisture. Tie down the full run of cable.

3 To prevent the risk of short circuits, disconnect other wiring from the

negative (–) battery terminal before connecting the transceiver.

FIXEd STATION

n

Operation Panel Installation

1 Attach the panel holder to the base stand using the 2 supplied SEMS

screws.

2 Attach the operation panel to the panel holder so that it locks in place.