94 ● appendices – Kenwood TS-870S User Manual

Page 100

Advertising
background image

94

APPENDICES

1

Sets RIT OFF/ON or reads status.

RT

RIT

2

Parameter Format

Parameter function

P1

1

RIT OFF/ON

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

R

T P1

R

T P1

;

R

T

;

4

5

6

7

8

9 10 11 12 13 14

;

1

Sets or reads RF ATT(attenuator).

RA

RF ATTENUATOR

2

Parameter Format

Parameter function

P1

48

ATTENUATOR

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

R

A

P1

;

R

A

;

4

5

6

7

8

9 10 11 12 13 14

P1

R

A

;

1

Sets the RIT frequency shift to 0.

RC

2

Parameter Format

Parameter function

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

R

;

4

5

6

7

8

9 10 11 12 13 14

RIT CLEAR

C

Note:
This command also clears the XIT
frequency (same as RIT shift).
The command functions independently
from the RIT/XIT control.

1

Selects receive/transmit mode.

RX

2

Parameter Format

Parameter function

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

;

;

TX

RX, TX

RX/TX

RX/TX

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

Lowers/raises RIT frequency.

RD

2

Parameter Format

Parameter function

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

R

;

4

5

6

7

8

9 10 11 12 13 14

RU

RIT DOWN/UP

D/U

Note:
This command also affects the XIT
frequency (same as RIT shift).
The command functions independently
from the RIT/XIT control.

1

Sets Scan OFF/ON or reads status.

SC

SCAN

2

Parameter Format

Parameter function

P1

1

SCAN OFF/ON

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

S

C P1

S

C P1

;

S

C

;

4

5

6

7

8

9 10 11 12 13 14

;

1

Sets or reads RF gain.

RG

RF GAIN

2

Parameter Format

Parameter function

P1

31

RF GAIN

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

R G

P1

;

R G

;

4

5

6

7

8

9 10 11 12 13 14

P1

R G

;

1

Sets or reads Semi Break-in delay time.

SD

SEMI BREAK-IN DELAY TIME

2

Parameter Format

Parameter function

P1

49

SEMI BREAK-IN
DELAY TIME

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

S

D

P1

;

S

D

;

4

5

6

7

8

9 10 11 12 13 14

P1

S

D

;

1

Selects a meter function or reads meter values.

RM READ METER

2

Parameter Format

Parameter function

P1

24

METER SWITCH

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

R M P1

;

R M

;

4

5

6

7

8

9 10 11 12 13 14

P1

R M

;

P2

P2

22

METER VALUE

1

S-meter and TX RF meter readings.

SM

S-METER

2

Parameter Format

Parameter function

P1

22

S-METER
VALUE

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

S M

P1

;

S M

;

4

5

6

7

8

9 10 11 12 13 14