91 appendices – Kenwood TS-870S User Manual

Page 97

Advertising
background image

91

APPENDICES

1

Sets RX/TX (VFO A/B, memory channel).

FR

2

Parameter Format

Parameter function

P1

3

FUNCTION

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

F

P1 ;

F

P1 ;

F R/T ;

4

5

6

7

8

9 10 11 12 13 14

FT

FUNCTION RX, FUNCTION TX

R/T

R/T

1

Reads status of the transceiver.

IF

INFORMATION

2

Parameter Format

Parameter function

P1

P2

P3

P4

P5

P6

P7

P8

P9

P10

P11

P12

P13

P14

P15

4

5

1

1

7

11

2

3

1

1

1

14

FREQUENCY

NOT USED

RIT/XIT FREQUENCY

RIT OFF/ON

XIT OFF/ON

NOT USED

MEMORY CHANNEL

TX/RX

MODE

FUNCTION

SCAN OFF/ON

SPLIT OFF/ON

TONE OFF/ON

TONE NUMBER

NOT USED

3

4

5

6

7

8

9 10 11 12 13 14

15

Input commands

Function

Output commands

Set

command

Read

command

Answer command

16 17 18 19 20 21 22 23 24 25 26 27 28

1

2

3

I

F

;

4

5

6

7

8

9 10 11 12 13 14

15 16 17 18 19 20 21 22 23 24 25 26 27 28

1

2

3

4

5

6

I

F

P1

7

8

9 10 11 12 13 14

15 16 17 18 19 20 21 22 23 24 25 26 27

P7

P4

P3

28

29 30 31 32 33 34

P8 P9 P10 P11 P12 P13

35

P14

36 37 38

;

39 40 41 42

P5

1

Fine function OFF/ON

FS

FINE STEP

2

Parameter Format

Parameter function

P1

1

FINE OFF/ON

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

F

S P1 ;

F

S P1

;

F

S

;

4

5

6

7

8

9 10 11 12 13 14

1

Sets or reads IF shift. For SSB and AM, sets or reads the low-pass filter
cut-off frequency.

IS

IF SHIFT

Note:
If P2 is positive or zero, P1 can be “+” or “ ”.

Allowable data (in units of Hz):
SSB: 1400, 1600, 1800, 2000, 2200,
2400, 2600, 2800, 3000, 3400, 4600, 6000

AM: 2500, 3000, 4000, 5000, 6000,
7000,

CW: 400~1000 (50 Hz steps)

2

Parameter Format

Parameter function

P1

P2

40

41

IF SHIFT
DIRECTION
IF SHIFT
FREQUENCY

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

I

S P1

P2

;

I

S P1

P2

;

I

S

;

4

5

6

7

8

9 10 11 12 13 14

1

Sets or reads keying speed while using the KY command.

KS

KEYER SPEED

2

Parameter Format

Parameter function

P1

42

KEYER SPEED

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

K

S

P1

;

K

S

;

4

5

6

7

8

9 10 11 12 13 14

P1

K

S

;

1

Sets or reads filter bandwidth. For SSB and AM, sets or reads the
high-pass filter cut-off frequency.

FW FILTER WIDTH

2

Parameter Format

Parameter function

P1

38

FILTER WIDTH

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

F W

P1

;

F W

;

4

5

6

7

8

9 10 11 12 13 14

P1

F W

;

Note:
Allowable data(units of 10 Hz):
SSB:
CW:
FSK:
FM:
AM:

0, 5, 10, 20, 30, 40, 50, 60, 80, 100
5, 10, 20, 40, 60, 100
25, 50, 100, 150
500, 600, 800, 1000, 1200, 1400
0, 10, 20, 50

1

Sets or reads AGC time constant.

GT

AUTO GAIN CONTROL TIME CONSTANT

2

Parameter Format

Parameter function

P1

39

AGC TIME CONSTANT

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

G

T

P1

;

G

T

;

4

5

6

7

8

9 10 11 12 13 14

P1

G

T

;

1

Reads Model number of the transceiver.

ID

IDENTIFICATION

2

Parameter Format

Parameter function

P1

16

MODEL NUMBER

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

I

D

P1

;

I

D

;

4

5

6

7

8

9 10 11 12 13 14

1

Converts input characters into Morse code.

KY

CW KEYING

2

Parameter Format

Parameter function

P1

43

KEYER MESSAGE

KEYER BUFFER

3

4

5

6

7

8

9 10 11 12 13 14

15

Input commands

Function

Output commands

Set

command

Read

command

Answer command

16 17 18 19 20 21 22 23 24 25 26 27 28

1

2

3

4

5

6

7

8

9 10 11 12 13 14

15 16 17 18 19 20 21 22 23 24 25 26 27 28

1

2

3

4

5

6

K

P1

7

8

9 10 11 12 13 14

15 16 17 18 19 20 21 22 23 24 25 26 27 28

29 30 31 32 33 34

P2

35 36 37 38 39 40 41 42

;

;

;

K

K

Y

Y

Y

P2

44

Note:

The Set command requires a " " (ASCII

code 20h) in the third byte position.

Insert " " for bytes that have no

characters to make a 28-byte fixed length

command.

The " " bytes will not send any character.

Supported characters include: Letters,

numbers, " ' (( )) ( )

+

,. / : = ?

The internal buffer allows approximately

5 times 28 characters (~140 characters) to be

continuously keyed. For programs that

convert to Morse code immediately after entry,

more continuous keying is possible

Ex:

CQ CQ CQ DE WD6DJY WD6DJY WD6DJY K

KY_CQ_CQ_ CQ_DE_ WD6DJY_ WD6DJ;

KY_Y_ WD6DJY_K_______________ ;

Advertising